Operating Instructions
Model 6123—Motorized Electronic Combination Lock
If you do not want your 6123 to have time delay override capability,
use the following programming sequence to permanently remove it:
8 3
*
1 2 3 4 5 6 #
1 # 1 #
The lock will emit three rapid beeps after the final # is pressed to
acknowledge that the time delay override capability has been
irrevocably removed. If you don’t hear those three beeps, or
if you hear a long tone (called a “brap”) while following this
procedure, either you’ve made an error in the entry sequence, or
the master code has already been changed.
A single user time delay override code allows the holder of
the code to enter it into the lock and immediately gain access to the
safe. He does not have to wait for the time delay, and there are no
other actions required.
To program the lock for single user time delay override, use the
following procedure:
4 6
*
1 2 3 4 5 6 #
2 # 2 #
The lock will emit three rapid beeps after the final # is pressed to
acknowledge that the single user time delay override capability has
been set. If you don’t hear those three beeps, or if you hear a long
tone (called a “brap”) while following this procedure, either you’ve
made an error in the entry sequence, or the master code has already
been changed.
A dual control time delay override is somewhat similar, with
one restriction placed on it. The override code will only open the
safe when it is entered within one minute of another code holder
entering his or her code to start the time delay. For example, when
the armored car shows up at the safe, a store employee would enter
the master code, the supervisor code, or any user code to start
the locks time delay. Within one minute, the armored car person
would enter his code. The safe would immediately open, rather than
enforcing the entire time delay period.
The dual control time delay override is often preferred, because it
imposes a supervisory restriction on the only person who has a code
that will circumvent the time delay. To set the lock for dual control
time delay capability, press:
4 6
*
1 2 3 4 5 6 #
1 # 1 #
The lock will emit three rapid beeps after the final # is pressed to
acknowledge that the dual control time delay override capability
has been set. If you don’t hear those three beeps, or if you hear a
long tone (called a “brap”) while following this procedure, either
you’ve made an error in the entry sequence, or the master code has
already been changed.
Once you’ve successfully set a management reset code (if
desired) and a time delay override method (or deleted the
capability permanently), you can perform any of the lock’s other
programming functions, including changing the master code.
Any programming you do from this point on can be changed.
Either type of time delay override still requires you to select and
set the actual six-digit TDO code number that will be used to open
the safe. Even if the capability for TDO has been programmed, it is
useless until a code is programmed. The code can be set, changed,
or deleted at any time by the holder of the locks master code. It
is easiest to set the time delay override code before a time delay
period is programmed. To do so, press:
Press SG
*
(_____) #
9
*
(____) #
(____) #
If a time delay period is already programmed into the lock, the time
delay override code can only be set, changed, or deleted during the
opening window, which is explained later in the manual.
Access methodsmodes of operAtion
single user mode
One person with a single, valid, six-digit code can open the lock. Lock
features can include time delay and time delay override code, if
desired. The holder of the master code can perform all programming
functions. The holder of the supervisor code (if it’s set) can set,
change, and delete user codes. He can also change and delete his
own code. User code holders can change their own codes. Your lock
left S&Gs factory in single user mode (the default mode). If its in
another mode and you want to change it to single user mode, follow
this programming sequence:
3 2
*
(_____) #
0 #
0 #
existing master code new TDO code(7 4)
existing master code
new TDO code
Page view 16